Products : Series 2000 : Hingeway Doors |
Specifications
Luxury - Elegance - Durability
The frame is constructed from hollow steel sections and designed in accordance with AS1170-1981, AS1250-1981 to withstand wind loading of 0.5kPa in the closed position and provide minimum deflection in the open position.
Applications:
Suitable where minimal internal projection is required.
Operation:
Two leaf hinged horizontally, counterbalanced with counterweights under constant suspension. Door movement is controlled by guide roller operating in 60 x 70 x 60 x 3m guide channels.
Size:
Maximum height - 6,000mm
Maximum width - 10,000mm
Cladding (Steel):
Doors can be clad with various sheeting materials. Standard Colorbond profiles are commonly used, however specialized profiles can be used. Please consult the manufacturer on the use of non standard sections.
Cladding (Glass):
Doors can be partially or fully glazed for viewing or showroom display and are glazed in accordance with AS1288. Standard glazing uses 6.38mm laminated safety glass. The use of other glass or glazing material should be referred to the manufacturer due to additional considerations caused by weight, deflection, door design and construction. Glazed doors will generally incorporate a kickplate in the base of the bottom leaf. Door size and weight will determine kickplate height.
Bar Grille:
This door is constructed of standard RHS frame covered with 20mm square hollow steel tube welded vertically over the entire door face at approximately 120mm centers.
Other Cladding:
Other available cladding commonly used are plywood, mesh, perforated sheet, woven wire and galvanized sheet.
Finishes:
Standard finish on frames and channels is epoxy primed and polyurethane. On glazed doors beading can be anodized or powdercoat finish. Other finishes are available if required, please inquire for other available options.
Locking:
By use of internal padbolts unless otherwise specified. Motorized doors will not be fitted with locks.
Counterweight Covers:
The counterweights shall be protected and covered with a removable pressed sheet to meet design requirements.
OPTIONAL EXTRAS
Escape & Access Doors:
Can be incorporated into door design providing bottom leaf height is sufficient. Locking is by a night latch unless otherwise specified. It is recommended that access doors open outward on a Series 2000 door.
Motorization:
Operation by a ramp and carriage designed for smooth opening and closing. The carriage is driven by an overhead shaft connected to a three or single phase drive unit incorporating open and close limit switches.
Renlita Overhead Doors has a continuous program of product development and reserves the right to change specifications at any time without notice.
|